Home
> Gas Filters—FC Series
|
Swagelok® Gas Filters—FC Series FC series gas filters are available for coalescing or particle filtration service to remove liquid or particulate contaminants.
|
Specifications Working Pressure Differential Pressure Temperature Body Material Element • Material
• Nominal Pore Size • Particulate Efficiency End Connections • Type
• Size |
Up to 1000 psig (68.9 bar) 2 psi (0.13 bar) 0 to 400°F (–17 to 204°C) 316 stainless steel
Borosilicate glass fiber with epoxy or silica binder 0.1, 0.3, 1.0 µm 99.99 %
Female Swagelok tube fitting, female NPT, female ISO 1/8 and 1/4 in.; 6 mm | More Information Download the Gas Filters—FC Series catalog. Find coalescing and particle filters in the product search.
Other Filters General-service all-welded inline, inline, and tee-type filters Ultrahigh-purity gas filters
Features
- Designed for on-line process analyzers.
- Easy element replacement.
- Horizontal mounting reduces panel space requirements.
- Drain connection port located on body eliminates need to disconnect line when changing elements.
- Stainless steel construction enhances system cleanliness.
- Captured bowl nut can be assembled hand-tight or wrench-tight.
- Bowl-to-body O-ring seal is available in fluorocarbon FKM, PTFE, and Kalrez® for a broad range of chemical compatibility.
- Perforated sleeve
- provides rigid support for filter element
- allows unobstructed fluid flow.
- Element-to-bowl seal
- centers element
- prevents bypass flow
- minimizes element deformation
|
|
Coalescing Filtration Orientation of the filter housing is critical for proper operation. The drain port must face down. 1 Gas stream enters side port and moves through filter element from inside to outside. 2 Filter element captures fine liquid droplets suspended in the gas forcing them to coalesce (form large drops) within filter element. 3 Large drops are forced to outside of element by gas flow. Gravity forces the drops to fall away from the element. 4 Liquid exits out drain port. 5 Dry, filtered gas exits through top port and flows to process analyzer. |
Particle Filtration Orientation of the filter is not critical for proper operation. 1 Gas stream enters top port and moves through filter element from outside to inside 2 Filter element captures any particulate suspended in gas. Only a small volume of gas passes through the element. 3 Filtered gas exits side port and flows to the process analyzer. 4 Most gas bypasses filter element, exits through bottom port, and returns to process line. | Cleaning and Packaging All FC series filters are cleaned in accordance with Swagelok Standard Cleaning and Packaging (SC-10).
Options - Special Cleaning and Packaging (SC-11)
- FC series gas filters are available with optional cleaning and packaging in accordance with Swagelok Special Cleaning and Packaging (SC-11), to ensure compliance with product cleanliness requirements stated in ASTM G93 Level C.
- O-Ring Materials
- Fluorocarbon FKM is standard. PTFE and Kalrez are available.
|
|
|
|
|
|